- Diode Dynamics SS30 Pro 30" driving12.9 A each1
1 lights
one relay
8 ft run
12.9 A
1 × Diode Dynamics SS30 Pro 30" driving- Fuse: 20 A blade fuse in an inline holder, within 7 in of the battery.
- Relay: 30 A automotive relay (Bosch style, 4 or 5 pin).
- Power and ground wire: 16 AWG copper, red for power, black for the ground lead. 4.7% voltage drop over the 8 ft run.
- Switch side: any AUX switch can trigger the relay; AUX5 (5 A) keeps the bigger circuits free.
Swipe to see the whole diagram.
At 12.9 A this is more than 75% of every 2021+ F-150 Raptor (Gen 3) or Tremor AUX circuit (the biggest is 15 A), so the relay is required. Ratings from the Ford 2022 and 2024 F-150 owner's manuals (lower of the two published figures); find the AUX wires.
Parts list
- 30 A automotive relay, 20 A fuse and holder, about 14 ft of 16 AWG (red and black)
- Ring terminals for the battery and a chassis ground, heat-shrink butt connectors, split loom
- About 15 ft of 18 AWG to reach the AUX wire for the relay trigger
Most light kits include a harness with a relay, fuse and switch. Check its wire gauge against the number above before you use it on a long run.
| Load | Fuse | 8 ft run | 12 ft run | 18 ft run | 22 ft run |
|---|---|---|---|---|---|
| 3 A | 5 A | 18 AWG | 18 AWG | 18 AWG | 18 AWG |
| 5 A | 7.5 A | 18 AWG | 18 AWG | 16 AWG | 16 AWG |
| 8 A | 10 A | 18 AWG | 16 AWG | 14 AWG | 14 AWG |
| 10 A | 15 A | 16 AWG | 14 AWG | 14 AWG | 12 AWG |
| 13 A | 20 A | 16 AWG | 14 AWG | 12 AWG | 12 AWG |
| 15 A | 20 A | 14 AWG | 14 AWG | 12 AWG | 12 AWG |
| 20 A | 25 A | 14 AWG | 12 AWG | 10 AWG | 10 AWG |
| 25 A | 35 A | 12 AWG | 12 AWG | 10 AWG | 8 AWG |
| 30 A | 40 A | 10 AWG | 10 AWG | 8 AWG | 8 AWG |
How the calculator works
Load is the sum of each light's amp draw from the maker's spec sheet, as listed in our light database. Where a maker lists only watts, we divide by 13.5 V. Budget bars often quote a rated wattage well above their real draw, which makes the wire bigger than strictly needed; that errs on the safe side.
Fuse is the next standard blade fuse at or above 125 percent of the load, so it never blows at normal draw but still blows before the wire overheats. Wire is the thinnest copper gauge that is rated for at least the fuse and keeps voltage drop at or under 5 percent (0.6 V). We count the power run plus a 3 ft ground lead to the chassis next to the lights. Ratings are the ABYC E-11 figures for 105 C insulated copper wire, cut 15 percent for engine bay heat.
Circuits: one relay circuit carries up to 32 A of lights, which is 80 percent of a 40 A relay and fuse. Anything bigger is split onto more than one relay.
This is a sizing guide, not a substitute for the light maker's instructions. If the maker calls for a bigger fuse or wire than this page, use theirs.